Setting up your Pentair 5600SXT Series Water Softener for the first time involves a few straightforward steps. Begin by ensuring the control panel is plugged in and that the bypass valve is set to the "In Service" position. Next, initiate a manual regeneration cycle by pressing and holding the "Extra Cycle" button for about 5 seconds. Advance the valve to the "Backwash" position and allow the drain line to flow steadily for approximately 10 minutes, or until the water runs clear. Following backwash, move the valve to the "Brine/Slow Rinse" position and confirm that the unit is drawing water from the brine tank; this step might need to be repeated. Then, move to the "Rapid Rinse" position; check the drain line flow, and run for around 5 minutes, or until the water runs clear. After that, position the valve to begin the brine tank fill cycle and confirm that water is entering the brine tank at the appropriate rate. The brine valve drive will keep the valve in this position to fill the brine tank for the initial regeneration. After this is complete, replace the control box cover. Lastly, add salt to the brine tank, but be sure to avoid using rock salt. By carefully following these steps, you can successfully start up your Pentair 5600SXT Series Water Softener.