To ensure your Siemens CLS-10D Color Light Signal operates at its best, proper lamp alignment is key. Here's a step-by-step guide:
Initial Beam Alignment: Begin by using sighting device A, found on the upper left-hand corner of the lamp unit. This will help you get the beam pointed in the right general direction. If you have multiple lamp units, the sighting device will be located on the bottom unit, and stacks of two or more lamp units are typically factory aligned.
Adjusting with Mounting Brackets: Both vertical and horizontal alignments are possible using the mounting brackets:
Side-of-Wall Mounting: If you're using side-of-wall brackets, attach the brackets to the lamp unit(s) before mounting to the wall. Hold the unit(s) against the wall and align them vertically, marking the hole locations. Use flat washers to shim the brackets if needed for horizontal alignment. Finally, secure the unit(s) to the wall using appropriate mounting hardware. Following these steps will help you get the best performance from your Siemens CLS-10D Color Light Signal.