To configure the current outputs on your PoolManager controller using the PM5-SA4 4-20mA plug-in module, follow these steps:
- Access the Configuration Menu: Press the "Menu" button on your PoolManager controller.
- Navigate to Communication & Interfaces: Scroll to and select the "Communication & Interfaces" submenu.
- Select Current Outputs: Choose the "Current outputs 4-20mA" submenu.
- Choose Your Measurement: Select the current output corresponding to the measurement you want to configure. For example, choose "Current output pH" if you're setting up the pH output.
- Configure Output Parameters: Within the selected measurement's submenu, you can adjust these parameters:
- Current Output: This option varies depending on the measurement being configured (e.g., pH, Cl, Br, mV, O2, T1).
- Minimum Value (at 4 mA): Set the minimum value for your desired measurement range.
- Maximum Value (at 20 mA): Set the maximum value for your desired measurement range.
Important Considerations: The current output is identified by the plug-in connector number (usually connector 1) and the current output number on the PM5-SA4 module. Default allocations are as follows:
- Current output 1.1: pH
- Current output 1.2: Cl or Br
- Current output 1.3: mV or O2
- Current output 1.4: temperature T1
The default minimum and maximum value settings are:
- pH: 0.00 pH to 10.00 pH
- Cl or Br: 0.00 mg/l to 10.00 mg/l
- mV: 0 mV to 1000 mV
- O2: 0 l to 10 l
- T1: 0°C to 50°C
Ensure you adjust the minimum and maximum values to match your specific measurement needs. Remember that a 4 mA current signal corresponds to the minimum value, while a 20 mA signal represents the maximum value. For detailed specifications and additional information, consult the BAYROL PM5-SA4 PoolManager PRO Analyt User Manual.