Installing the VISA LIGHTING CM1980-W Symmetry Ceiling Light in a sheetrock ceiling requires careful attention to detail. Here's a step-by-step guide:
Prepare the Opening: Start by creating a framed opening that will center the fixture. The recessed housing opening needs to measure 23-3/4" to properly support the light during installation.
Initial Fixture Setup: Remove the lens and trim frame. Secure the trim frame screws back to the recessed housing; you'll need them later. Then, remove the driver/wiring cover and the lamp plate.
Secure the Fixture: Use mounting screws through the slots in the recessed housing to secure the fixture to the ceiling structure. Adjust the fixture so that the bottom of the housing sits 1-3/8" above the finished sheetrock surface.
Make Electrical Connections: Connect all necessary electrical wiring, making sure to comply with local electrical codes.
Sheetrock Installation: Complete the sheetrock installation process. After the sheetrock is up, cut a circular opening for the trim frame. This opening should have a diameter between 22-5/16" and 22-9/16".
Final Assembly: Put the LED lamp plate back in place and secure it to the standoffs located in the recessed housing. Reattach the trim flange, making sure it extends from the sheetrock face by 1/16". Finally, reattach the driver/wiring cover and the lens assembly.
Thermal Protector Installation (If Applicable): If a thermal protector came with your light, remove the tape and insert the protector into the designated hole in the housing until it clicks into place. Be careful that the thermal protector does not touch the T-bar grid system.
Alternative Sheetrock Installation: Follow the sheetrock installation instructions provided (Sheet 4) in the manual, but skip the threaded rod support method. Following these steps ensures a successful and safe installation of your VISA LIGHTING CM1980-W Symmetry Ceiling Light.