Programming your PENTAIR OM34K OMNIFILTER High Efficiency Twin Tank Softener is straightforward. Here's a step-by-step guide:
Set the Time of Day: Begin by setting the current hour. Press the "Time" button until the correct hour (0-23) appears on the display.
Adjust the Recharge Time: The softener recharges at 2:00 AM by default. To change this, adjust the clock setting to initiate the recharge at your preferred time.
Choose Your Salt Setting: Press the "Salt" button to view your current setting (HC or HE). Press it again within 5 seconds to toggle between the options:
Input Your Water Hardness: Use the "Hardness" button to set the water hardness level. Pressing the button repeatedly (within 5 seconds each time) increases the setting by one grain per gallon. Holding the button will allow for faster adjustment.
Finalize the Settings: Once the time, salt setting, and water hardness are configured, the programming is complete. The system will now operate according to your settings.
Additional Considerations: