Setting up your Anolis Ambiane HP111 Surface Mount fixture involves several key steps. First, ensure installation is handled by a qualified electrician, adhering to all local and national electrical codes. Begin by preparing a circular opening in the ceiling for the control unit. The following steps will guide you through the process:
-
Installation & Connections:
- Mount the control unit above the ceiling, securing it through the opening.
- Connect the supply cable, DMX cable, and LED unit cable to the control unit's terminal blocks. Ensure all connections are secure.
- Make sure to install other terminal blocks needed for your specific setup.
-
Power and Data Connections:
- Primary power connection: Connect Vcc (Power +) and 0V (Power -).
- Secondary power connection: Also connect Vcc (Power +) and 0V (Power -).
- DMX connection: Attach D+ (Data +), D- (Data -), and 0V (Data ground).
- 0-10V connection: Use D+ (+10V) and 0V.
- Note that DMX connectors are utilized for 0-10V control.
-
DIP Switch Settings and Light Intensity:
- Adjust the trimmer to set your desired light intensity.
- Use the DIP switch to choose your operation mode (DMX, DALI, or 0-10V).
- DIP 10 ON activates test light mode; DIP 11 OFF selects DMX 512 and DALI, while ON enables 0-10V control.
-
DMX Addressing:
- Configure the DMX start address to receive commands from your DMX controller.
- You can set the DMX address via the DIP switch or RDM.
- The method used is indicated by the green LED.
-
Alternative Control Methods:
- DALI control: Use an external DALI controller for permanent control by addressing the fixture.
- 0-10V control: Set DIP 11 to ON to prioritize 0-10V commands over DALI and DMX commands.
-
RDM Operation:
- Your Anolis Ambiane HP111 supports RDM for bi-directional communication, allowing for software updates and more.
Following these steps, as detailed in the user manual, will enable you to connect and operate your Anolis Ambiane HP111 Surface Mount fixture based on your preferred control method.