Installing your Opticlimate REVOMAX II Classic PRO Series Style Housing correctly is crucial for optimal performance. Here's a step-by-step guide to help you get started:
Spacing Requirements: Maintain adequate spacing for efficient air circulation. Ensure at least 15cm (approximately 6 inches) of space between the unit's backside and the wall for air suction. Also, maintain a 15cm gap between the unit's top and the ceiling. Larger spaces are preferable to minimize any contact-related noise.
Mounting Methods: You have the flexibility to mount your Opticlimate REVOMAX II Classic PRO Series Style Housing in a few ways. You can suspend it from the ceiling using M8 or M10 metal threaded rods, along with a nut, washer, and rubber damper for vibration absorption. Alternatively, place it on a stand or frame, securing it with an M8 bolt and washer, ideally using a rubber damper.
Cable Routing: Access the electrical connection panel, usually found near the manometer. Route the necessary cables for the magnetic valve, water leakage sensor, automatic moisture meter, remote control, and room temperature sensor through the designated openings.
Electrical Connections: Connect the solenoid valve, water leakage sensor, automatic moisture meter, room temperature sensor, and remote control. Always refer to the provided instructions for correct wiring.
Power Supply Guidelines: Adhere strictly to the power supply specifications to ensure safety and proper functionality. Use the recommended circuit breakers and cable thickness. Connect the power supply cables to the designated terminal on the circuit board, usually marked as green.
Temperature Safeguards: Implement the high-temperature safeguard to automatically shut off heat sources if the room temperature exceeds safe levels. Follow the specific instructions for connecting the safeguard, often to a timer or control system.
Water Connections: Connect the water inlet to a cold water supply and the water outlet to a drain. Position a solenoid valve at the beginning of your piping system and ensure all water connections are securely installed.
Condensation : Proper handling of condensation water is important. Install a P-trap on the condensation outlet to prevent odors. If the unit is at or below the drain level, consider using a drain pump to efficiently remove condensation.
Smart Remote Controller Setup: Connect the power supply and USB connector from the remote cable to the Smart Remote controller. Follow the initialization steps in the manual to power up the unit and properly configure the Smart Remote controller. Following these steps will help to ensure a proper and efficient setup of your Opticlimate REVOMAX II Classic PRO Series Style Housing.