Programming your Automatic Technology FHCRX-1 Multi-Frequency Receiver for your garage door involves a few straightforward steps. Here's a guide:

  1. Setting Transmitter Type: You must first set the memory location for either ATA TrioCodeTM or BND Tri-TranTM transmitters, determining which type the receiver will accept.

  2. Storing Transmitter Codes:

    • On the receiver board, press and hold either SW1 (for Relay 1) or SW2 (for Relay 2). The LED will begin to flash.
    • Press the button on your transmitter that you wish to use for two seconds. The LED will flash more rapidly.
    • Release the transmitter button, pause for two seconds, and then press the same button again for two seconds. The LED will stay on for a second before turning off.
    • Release the SW button.
    • Test the operation by pressing the transmitter button; the garage door should now respond.
  3. Deleting a Single Transmitter's Code:

    • Press and hold SW1 or SW2 on the receiver board. The LED will flash.
    • Press the transmitter button you want to remove for two seconds. The LED will flash faster.
    • Release the transmitter button, wait two seconds, and press it again for two seconds. The LED will slowly flash twice.
    • Release the SW button.
    • Confirm the deletion by pressing the transmitter button; the garage door should not respond.
  4. Deleting All Stored Transmitter Codes:

    • Disconnect the power to the receiver.
    • Press and hold the SW1 button.
    • While holding SW1, restore power to the receiver. After 15 seconds, the Coding LED will illuminate, indicating the memory has been cleared.
    • Release SW1. All codes are now deleted. Verify by pressing the transmitters previously used.
Was this review help?
109
Share
More Q&A

How do I change the height of my ARKON MOUNTS HD8RV29PK Pro Stand phone holder?

Adjusting the height of your ARKON MOUNTS HD8RV29PK Pro Stand phone holder is simple. Here's how: First, locate the adjustment collar on the stand's pole. Then, turn the adjustment collar counterclockwise to loosen it. Next, extend or retract the telescoping pole to position the phone holder at your preferred height. Finally, secure the new height by tightening the adjustment collar clockwise. This will ensure your ARKON MOUNTS phone holder is perfectly positioned for optimal viewing or recording.
115
Share

How do I set the correct height for my island light during installation?

Adjusting the height of your island light fixture during installation is straightforward. This guide uses the ZEVNI A04518 Fido 28 Inch Wide Island Light as an example. First, detach the mounting plate: Unscrew the studs (G) from the canopy (H) and carefully remove the mounting plate (E), setting them aside. Next, manipulate the cords: Adjust the length of the cords (J) to position your fixture at the desired height. Then, use the Allen wrench (N) to loosen the screws in the strain reliefs (I). Gently pull or push the cords (J) through the canopy (H) and strain reliefs (I) to lengthen or shorten them. Once you've reached your desired height, securely tighten the screws. Following these steps ensures your ZEVNI island light is installed at the perfect height.
103
Share

How do I know when my Medisana HM 645 Hand Massager is fully charged

Knowing when your Medisana HM 645 Hand Massager is fully charged is simple. Just pay attention to the LED indicators on the device. Here's how to check the charging status: Plug the provided 9V/1A charging adapter into both the massager and a power outlet. The LED indicators will either light up or flash, showing the battery's current charge. Once the Medisana HM 645's battery is completely charged (this usually takes 2 to 3 hours), all four charging LEDs will glow blue continuously. Please note that the massager cannot be used while it's charging. By monitoring these LED indicators, you'll easily know when your Medisana HM 645 Hand Massager is ready for use.
119
Share

How do I correctly install crimping or cutting jaws on my HILTI 54-22 Cordless Hydraulic Crimper?

To properly install the crimping or cutting jaws on your HILTI 54-22 Cordless Hydraulic Crimper, please follow these steps: Safety First: Always begin by removing the battery from your HILTI 54-22 before installing, changing, or removing any jaws. This is crucial for your safety. Jaw Selection: Choose the correct crimping or cutting jaws designed for your specific task and materials. Jaw Insertion: a. Locate the locking pins on the crimping or cutting head of your HILTI tool. b. Press these locking pins inward. c. Rotate the locking pins counterclockwise until they release. d. Insert the chosen crimping or cutting jaws into their corresponding slots on the tool. e. Push the locking pins back in until they click and are securely engaged. The locking pins should slightly protrude on the opposite side of the jaws. Double-Check: Before you start any crimping or cutting work, carefully verify that the jaws are correctly positioned to ensure both effective operation and your safety. Following these steps will help you safely and correctly use the HILTI 54-22 Cordless Hydraulic Crimper.
118
Share

How do I attach a lantern to the GE 82055LO Christmas Pathway Marker hook?

To successfully hang a lantern on your GE 82055LO 3-Marker White Candle Christmas Pathway Marker, follow these straightforward steps. First, assemble the hook by connecting its lower and upper sections. Next, firmly insert the hook into the ground, ensuring both stakes are fully embedded for stability. Finally, with the hook securely in place, carefully hang your lantern. Following these steps, you should easily attach your lantern. If you need more help, check the included instructions or contact customer support.
111
Share

What is the correct installation procedure for HILTI HVU-TZ Capsule Adhesive Anchors?

Installing HILTI HVU-TZ Capsule Adhesive Anchors correctly is crucial for ensuring a secure and reliable fastening. Here's a step-by-step guide to help you through the process: Concrete Strength Check: Verify that the concrete you're working with has a minimum compressive strength of 15 N/mm² (2000 psi). This is essential for the anchor to perform as intended. Capsule Inspection: Before you begin, examine the capsules to ensure they are undamaged and within their expiration date. Using faulty capsules can compromise the anchor's performance. Hole Preparation: Thoroughly clean the drilled hole. Use an air jet to remove all drilling dust and any standing water. Contaminants like oil, bitumen, or chemicals can significantly reduce the anchor's load capacity. Threaded Rod Setting: Carefully insert the threaded rod into the capsule. Use a rotary hammering action with a speed between 250 to 1000 r.p.m. Apply moderate pressure and use a setting tool designed for this purpose. Stop the machine once the embedment depth is reached. Adhesive Fill: After setting the rod, check that the annular space is completely filled with adhesive up to the concrete surface. If no adhesive emerges, the anchor fastening may not be properly installed and should not be used. Avoid Disturbance: Do not disturb the anchor or remove any setting tools until the specified curing time has passed. This is vital for the adhesive to set correctly. Final Tightening: After the curing time, use a torque wrench to tighten the anchor to the manufacturer's recommended specifications. Only apply load after the curing time. Always follow these instructions precisely to ensure the HILTI HVU-TZ Capsule Adhesive Anchors perform safely and reliably. Remember to prioritize safety by adhering to all safety regulations and wearing appropriate protective gear during the installation process.
107
Share
Cookie
Cookie Settings
© 2025 Servanan International Pte. Ltd.