Log in / Register

How do I install the SCOTT TQ HPR Range Extender V01 160 Wh on my e-bike using the FIDLOCK system

1Answers
VanOlive
12/17/2025, 09:11:50 AM

To correctly install the SCOTT TQ HPR Range Extender V01 160 Wh on your e-bike with the FIDLOCK system, follow these steps: First, mount the FIDLOCK Bike Base to your e-bike frame. Use only the provided ISO 7380–1 M5 × 10 A2 button head screws, tightening them to a torque of 2 Nm, or as specified by your bike's manufacturer. Next, fasten the FIDLOCK Force Connector to the Range Extender using the provided ISO 4762 M4 × 16 A2 cylinder screws, tightening these to 1.0 Nm. Now, insert and lock the Range Extender onto the FIDLOCK Bike Base by placing it diagonally, ensuring the pin on the base slides into the connector's socket. An audible click confirms it's locked. Secure the Range Extender further by pushing the FIDLOCK system's locking tab fully in. Always lock it before riding. After that, connect the connection cable to the Range Extender's socket, fastening it with the provided M3 × 8 socket head screws. Be careful not to use longer screws to avoid damaging the electronics. Finally, connect the connection cable to your e-bike's charging port, aligning the connector and securing it with the cover. Following these steps ensures your SCOTT TQ HPR Range Extender V01 160 Wh is correctly and securely attached to your e-bike.

Was this review help?
120
Share
More Q&A

I've bought a TESY HPWH 3.2 100l Air-to-Water Heat Pump Water Heater Aquathermica Compact. How do I install it correctly?

Installing your new TESY HPWH 3.2 100l Air-to-Water Heat Pump Water Heater Aquathermica Compact involves several key steps to ensure optimal performance. First, choose a suitable location, adhering to the manufacturer's recommendations. Adequate ventilation and space for maintenance are crucial. Next, securely mount the unit following the manual's instructions, ensuring it's level and stable. For electrical connections, consult the circuit diagram in your manual, and it's highly recommended to have a qualified electrician handle this task for safety and code compliance. Plumbing connections involve linking the unit to your water supply and hot water distribution system; use appropriate fittings, and meticulously check for leaks. After installation, thoroughly test the system, checking for any unusual noises or leaks. Finally, familiarize yourself with the maintenance requirements outlined in the manual to ensure the longevity and efficiency of your TESY HPWH. Always refer to the specific instructions provided in the TESY HPWH 3.2 100l Air-to-Water Heat Pump Water Heater Aquathermica Compact manual for detailed guidance. If you're unsure about any step, don't hesitate to seek professional assistance.
103
Share

How do I connect my BOOX SHERD-01-9BA eReader to Wi-Fi and Bluetooth?

Connecting your BOOX SHERD-01-9BA 10.3 Inch E Ink eReader and Notepad to Wi-Fi and Bluetooth is straightforward. Here’s how: For Wi-Fi: Go to Settings on your device. Tap on "Wi-Fi" or access the Wi-Fi interface via the drop-down menu. Choose your Wi-Fi network from the list of available networks. If prompted, enter your Wi-Fi password. A Wi-Fi symbol on your device's screen confirms a successful connection. For Bluetooth: Open Settings on your BOOX device. Find the "Bluetooth" option and switch it on. Alternatively, access Bluetooth settings from the drop-down menu. Your device will search for available Bluetooth devices. Select the one you wish to pair with. Follow any on-screen instructions to finish the pairing process. By following these steps, you can easily enable internet access through Wi-Fi and connect to other devices via Bluetooth using your BOOX SHERD-01-9BA eReader.
105
Share

How can I adjust the sensitivity and timing on my VYNCO VMOSS-VMOSSB Ceiling Sensor?

Adjusting the sensitivity and timing of your VYNCO VMOSS-VMOSSB Flush Mount 360° Ceiling Sensor is straightforward. Here's a step-by-step guide: Setting the Controls: Ensure the sensor is fully installed according to the provided instructions. Set the time dial to its minimum setting (5 seconds) and the lux dial to its minimum setting (DAY). Turn on the power to the lights or load connected to the sensor. The lights may turn ON briefly (approximately 30 seconds) during the sensor's warm-up phase and then turn OFF. Test the sensor by walking through its coverage area. The connected lights or load should activate, confirming correct wiring and operational status. Adjust the time dial to your preferred duration setting. To set the ambient light level for activation, first set the lux dial to its minimum setting (night). When the ambient light reaches your desired level, have someone continuously walk through the detection zone while you gradually increase the lux dial. When the connected lights or load turn ON, release the dial. Functional Test During Daylight: Verify correct wiring by a qualified professional, following the installation guidelines. Set both the lux and duration time dials to their minimum settings. Completely cover the sensor using its original packaging to bypass the lux sensitivity control and activate the PIR. This will confirm the correct connection and activation of the load. Once the sensor activation is confirmed, adjust the lux and time dials to your desired settings. Following these steps will help you customize the VYNCO VMOSS-VMOSSB sensor to optimize its performance in your specific environment.
120
Share

How do I replace the blade on my Einhell GE-GS 18-150 Li-Solo Cordless Tree Pruning Saw?

To safely replace the saw blade on your Einhell GE-GS 18-150 Li-Solo Cordless Tree Pruning Saw, follow these steps: First, switch off the pruning saw and remove the battery pack to ensure safety. Next, open the safety guard by gently pressing it together at the front and swinging it upwards. Then, rotate the ring on the blade holder until the blade can be inserted into the slot. Once the blade is in place, make sure the ring returns to its original position. After that, give the blade a gentle tug to confirm it is securely seated. Finally, if required, attach the branch jaw clamp by inserting it into the lower mount of the soleplate and fastening it with the latching bolt. Always consult your Einhell GE-GS 18-150 Li-Solo's instruction manual for comprehensive details and safety guidelines before performing any maintenance.
117
Share

How do I install the Knightsbridge MLBA6045F LED bathroom mirror with frosted panels?

Installing your Knightsbridge MLBA6045F LED bathroom mirror with frosted panels is straightforward. Here’s a step-by-step guide to help you: Mark Fixing Hole Locations: Use the provided template to accurately mark the positions of the fixing holes on your bathroom wall. It’s crucial to ensure that you avoid drilling into any gas pipes, water pipes, or electrical cables for safety. Drill the Holes: Drill the marked holes into the wall and fully insert the wall plugs. Install Batteries: Remove the battery enclosure lid. Open the battery compartment by removing the cover and sliding it in the direction indicated by the arrow. Insert 8 x AA batteries (not included), making sure to observe the correct polarity (+ and -). Replace the battery compartment lid. Mount the Mirror: Carefully hang the mirror onto the fixing screws, ensuring it is secure. Switch On the Mirror: Locate the sliding switch on the outside of the battery compartment and set it to the ON position to power the mirror (see Fig. 2 in the instruction manual). Check Operation: Turn on the mirror and confirm that it is functioning correctly. If the LED lights do not illuminate, double-check the battery installation and the switch position. Maintenance: To keep your Knightsbridge mirror looking its best, clean it with a soft, dry cloth. Avoid using harsh cleaning products or solvents that could damage the mirror's finish. A glass cleaning solution can be used on the mirror surface if needed. For detailed guidance and important safety precautions, always refer to the complete instruction manual that came with your Knightsbridge MLBA6045F. If you have any difficulties or need further assistance, don't hesitate to contact the manufacturer or your supplier.
112
Share

What's the maximum time the Draper 18018 Carpet Protective Film can stay applied?

For optimal protection, the Draper 18018 Carpet Protective Film should generally be removed within four weeks of application under typical conditions. However, the lifespan of the film can be affected by environmental factors. In high-traffic areas or environments where temperatures regularly surpass 22°C (71.6°F), it's recommended to remove the film within one week. Adhering to these guidelines helps prevent potential issues like adhesive residue or damage to your carpeted flooring, ensuring the best possible protection from the Draper 18018 Carpet Protective Film.
103
Share