Installing your new Robinhood RIJ3CL9BKDC Island Rangehood? Here's a simplified guide based on the manual's instructions to help you through the process:
- Preparation: Before you start, gather all the tools and components listed in your Robinhood rangehood's manual. Safety first: disconnect and unplug the rangehood from the power supply.
- Placement: Decide where the rangehood will be installed above your cooktop. Aim for a distance of 60-75cm (65cm if you have a gas cooker) from the cooking surface.
- Ceiling Prep: Make sure your ceiling is sturdy enough to hold the rangehood (at least 120kg weight capacity and a minimum thickness of 30mm). Drill a 170mm diameter hole in the ceiling.
- Hanging Board Installation: Refer to the manual for the hanging board's image. Drill 12 holes in the ceiling according to the provided picture. Secure the hanging board to the wooden ceiling using 12 ST6*40mm screws.
- Angle Iron Assembly: Attach the angle irons to the hanging board using 8 M410mm screws, nuts, and gaskets. Then, connect the two angle irons with 16 M410mm screws, nuts, and gaskets, determining the appropriate length.
- Expansion Pipe: Guide one end of the expansion pipe through the 170mm ceiling hole.
- Chimney Attachment: Use 4 ST4*8 screws to connect the inner chimney to the hanging board. Place the outer chimney and hold it up with a hook.
- V-Flap Assembly: If not already assembled, install the V-flap according to the manual's instructions. Insert the half-parts into the rangehood body and secure the axis.
- Hood Body Connection: Secure the hood body to the angle iron using 16 M4*10 screws.
- Final Connections: Attach the expansion pipe to the outlet and connect the power supply.
- Finishing Up: Ensure the expansion pipe is correctly positioned on the outlet. Remove the hook and the outer chimney.
Following these steps should help you successfully install your Robinhood RIJ3CL9BKDC Island Rangehood. Always prioritize safety, and consult your rangehood's manual for detailed instructions and safety advice.