Adjusting the sensitivity and timing of your VYNCO VMOSS-VMOSSB Flush Mount 360° Ceiling Sensor allows you to optimize its performance. Here's how, based on the instruction manual:
-
Setting the Controls:
- Make sure the sensor is fully installed.
- Set the time dial to its minimum (5 seconds) and the lux dial to its minimum (DAY).
- Turn on the power to the lights or load connected to the sensor. The light might turn ON briefly (30 seconds) while the sensor warms up, then OFF.
- Walk through the sensor's coverage area. The connected lights or load should turn ON, confirming correct wiring and operation.
- Adjust the time dial to your desired setting.
- To set the ambient light level at which the sensor activates, turn the lux dial to minimum (night). When the room light reaches your desired level, have someone continuously walk through the detection zone while you increase the lux dial. Stop when the connected light or load turns ON.
-
Functional Test During Daylight Procedure:
- Ensure proper wiring by a qualified person, following the installation instructions.
- Set both the lux and duration time dials to minimum.
- Cover the sensor completely with the VMOSS packaging to bypass the lux sensitivity control and activate the PIR. This tests the load connection and activation.
- Once sensor activation is confirmed, adjust the lux and time dials to your preferred settings.
By following these steps, you can tailor your VYNCO VMOSS-VMOSSB Flush Mount 360° Ceiling Sensor to perform optimally in your environment.