To adjust the water level and flush settings on your American Standard 204AA Edgemere 2-piece toilet, consult the instruction manual for precise guidance. Here's a general overview:
Water Level Adjustment:
For Single Flush Models: Adjust the water level by turning the water level adjustment mechanism to move the float cup up or down, matching the level indicated on the tank.
For Dual Flush Models: Fine-tune the water level by adjusting the float cup using the water level adjustment mechanism.
Flush Valve Setting Adjustments:
Without Liner Tank: Full Flush: Set to 2. Lite Flush: Set to 2.5. Note: Other settings may affect water usage; the recommended settings are provided for optimal performance.
To Remove and Reinstall Flush Valve: Apply gentle downward pressure and twist the flush valve until it detaches from the bayonet fitting. To reinstall, reverse this process.
Flush Buttons on Tank: Pressing both flush buttons simultaneously activates the low-flush mode, typically using 1.0 gallon/flush or 3.8 liters/flush. Ensure the Lite Flush Button (with 3 dots) aligns over the blue actuator on the flush tower, and the Full Flush Button (with 9 dots) aligns over the white actuator.
Troubleshooting: For issues with flushing, water levels, or leaks, the manual provides troubleshooting steps to identify and resolve common problems. Following these steps helps optimize your American Standard Edgemere 204AA toilet's performance.