Adjusting the sensitivity and timing of your VYNCO VMOSS-VMOSSB Flush Mount 360° Ceiling Sensor is straightforward. Here's a step-by-step guide:
-
Setting the Controls:
- Ensure the sensor is fully installed according to the provided instructions.
- Set the time dial to its minimum setting (5 seconds) and the lux dial to its minimum setting (DAY).
- Turn on the power to the lights or load connected to the sensor. The lights may turn ON briefly (approximately 30 seconds) during the sensor's warm-up phase and then turn OFF.
- Test the sensor by walking through its coverage area. The connected lights or load should activate, confirming correct wiring and operational status.
- Adjust the time dial to your preferred duration setting.
- To set the ambient light level for activation, first set the lux dial to its minimum setting (night). When the ambient light reaches your desired level, have someone continuously walk through the detection zone while you gradually increase the lux dial. When the connected lights or load turn ON, release the dial.
-
Functional Test During Daylight:
- Verify correct wiring by a qualified professional, following the installation guidelines.
- Set both the lux and duration time dials to their minimum settings.
- Completely cover the sensor using its original packaging to bypass the lux sensitivity control and activate the PIR. This will confirm the correct connection and activation of the load.
- Once the sensor activation is confirmed, adjust the lux and time dials to your desired settings. Following these steps will help you customize the VYNCO VMOSS-VMOSSB sensor to optimize its performance in your specific environment.