Log in / Register

What are the key FCC and IC compliance steps when integrating the Texas Instruments CC2652PSIP module?

1Answers
VonDaniella
12/17/2025, 06:47:01 PM

Integrating the Texas Instruments CC2652PSIP module into your product while adhering to FCC and IC regulations requires careful attention to several key areas. Here's a breakdown to guide you:

  1. Antenna Placement: Maintain a minimum separation distance of 20 cm between the antenna and any user of the end product. Avoid co-locating the CC2652PSIP module's transmitter with any other transmitters or antennas within your design.

  2. RF Transmission Power: Ensure that the maximum RF power transmitted in the 2.4 GHz band does not exceed 10 dBm. The antenna gain, accounting for any cable loss, must not surpass 5.3 dBi for low-power PA or 3.3 dBi for high-power PA in the 2.4 GHz band.

  3. Certification Requirements: Follow the FCC and IC certification conditions specified for OEM integrators. This includes correctly labeling the end product with the appropriate FCC ID and IC information. If specific configurations prevent you from meeting the regulatory conditions, re-evaluation and separate authorization may be required.

  4. RF Radiation Exposure: To comply with FCC and IC RF radiation exposure limits, maintain a minimum distance of 20 cm between the radiator (antenna) and the user's body. Also, adhere to the guidelines for device classifications (e.g., portable versus mobile devices) and consider consulting regulatory test labs if necessary.

  5. End Product Labeling: Clearly display the required FCC ID and IC information on the host system via visible labels to ensure compliance. By following these guidelines, you can help ensure your product meets the necessary regulatory standards for RF transmission and certification when incorporating the Texas Instruments CC2652PSIP module.

Was this review help?
109
Share
More Q&A

How do I use the MAJOR TECH MT235 to test a 9V battery?

Testing a 9V rectangular battery with the MAJOR TECH MT235 Battery Tester is straightforward. First, identify the battery's polarity; the positive terminal is usually marked with a plus sign (+), and the negative with a minus sign (-). Next, ensure the battery selector on the MT235 is set to the 9V position. Then, align the battery terminals with the corresponding contacts on the tester, the positive (+) and negative (-) terminals of the 9V battery should connect with the positive and negative contact points on the tester. Finally, observe the LCD display for the voltage reading, which indicates the battery's condition. Consult the MT235's manual for voltage ranges to determine if your 9V battery is in good condition.
107
Share

How can I adjust the fan speed on my Mitsubishi Electric MSZ-FS15NA air conditioner?

To modify the fan speed on your Mitsubishi Electric MSZ-FS15NA wall-mounted air conditioning unit, utilize the included remote control. The system offers several fan speed settings to ensure optimal comfort, including Quiet, Low, Medium, High, Super-high, and Auto modes. Simply use the remote's interface to select your preferred fan speed. For added convenience, the MSZ-FS15NA also supports multiple control methods beyond the remote. These include the kumo cloud® app, which allows for smart device control, as well as compatibility with third-party interfaces and wired or wireless controllers. For detailed instructions and specific guidance on fan speed adjustment, please consult the user manual for your Mitsubishi Electric MSZ-FS15NA model.
114
Share

What is the proper way to store the Easy Plate EC test kit, including temperature and shelf life considerations?

To maintain the efficacy of your Easy Plate EC test kit, proper storage is crucial. Before opening the aluminum bag, refrigerate the kit between 2-8°C. Alternatively, storage below 25°C is acceptable for up to 14 days, or below 30°C for up to 5 days, prior to opening, although these conditions haven't been validated under AOAC Research Institute PTM 031601. Once the aluminum bag is opened, place any unused sheets back into the bag. Fold the bag's end over twice and seal it with tape. The shelf life under refrigerated conditions is 3 months after opening. The expiry date, found on the product label after "EXP," indicates the kit's shelf life. When stored properly and unopened, the Easy Plate EC test kit has an 18-month shelf life from the manufacturing date. Following these storage guidelines helps ensure the reliability of your Easy Plate EC test kit for your testing procedures.
108
Share

How do I safely attach my bookcase to the wall to prevent it from tipping?

To ensure your bookcase's stability and prevent potential hazards, securing it to the wall is essential. The hardware included (C, H, G, and J) is designed for this purpose. Here's how to properly attach your bookcase: First, locate the appropriate wall attachment hardware (C, H, G, and J) that came with your bookcase. Next, position the bookcase where you want it against the wall. Then, use the provided hardware and a suitable tool to attach the bookcase to the wall, carefully following the included instructions. Once attached, ensure the bookcase is stable before placing any items on it. Regularly check the attachment and re-tighten if needed to maintain safety and stability.
103
Share

How do I assemble my RL live your light R407810XX Floor Lamp?

Assembling your RL live your light R407810XX Floor Lamp is straightforward. For a safe and correct setup, adhere to these steps: First, carefully review all safety precautions in the instruction manual. Next, verify that all components are present and undamaged. Begin assembly by placing the lamp base on a stable surface. Attach the lamp pole to the base, using any provided tools as instructed. Securely connect the lamp head or shade to the stand. If your lamp includes extra parts or accessories, follow the accompanying specific instructions. If electrical connection is needed, follow the wiring instructions precisely, ensuring the lamp is unplugged during assembly. After complete assembly, double-check all connections for stability and balance. Finally, plug the lamp into a power source and test its functionality. For troubleshooting or additional support, consult the contact details for Reality Leuchten GmbH or the distributor, as provided in the manual.
105
Share

How do I connect my Lindab Wireless Sensor SEPTH to the main unit?

To get your Lindab Wireless Sensor SEPTH working, you'll need to pair it with the main unit. Here’s how, based on the Lindab Wireless Sensor SEPTH instruction manual: Get the Sensor Ready: First, put the batteries in the sensor, making sure they're in the right way. Start Pairing Mode: Find the pairing button on the sensor. Press and hold it until the light on the sensor starts blinking quickly. Set Up the Main Unit: Go into the settings on the main unit that deal with sensors. Pairing Time: Follow the instructions on the main unit to look for sensors. When it finds your sensor, choose it to start the pairing. Check for Success: The main unit should tell you when the pairing is done. Make Sure It Works: Test the sensor. For example, if it measures temperature, see if it shows the right temperature. Following these steps should help you successfully connect your Lindab Wireless Sensor SEPTH to the main unit.
116
Share