To properly connect the Satel XD-2L Multipurpose Universal Detector for both alarm and tamper functionalities, follow these steps. First, and most importantly, disconnect the power supply to prevent any electrical hazards. Next, securely mount the detector to your chosen surface using appropriate screws and wall plugs. Wiring the detector involves connecting wires to specific terminals. Here's how to do it: Connect the black wire to the 12V DC (-) terminal, the red wire to the 12V DC (+) terminal, the green wire to the tamper alarm NC contact, and the yellow wire to either the alarm NO or NC contact, depending on your desired operational mode. If you are using the detector for water leakage detection, be sure to attach the probe as outlined in the manual. Once all connections are made, you can restore power to the detector. Finally, test the alarm and tamper functions to confirm the correct operation of the Satel XD-2L. For a comprehensive understanding and troubleshooting tips, always refer to the full manual, available on www.satel.pl. Should you need further assistance, don't hesitate to consult a qualified professional.