To configure the current outputs for your desired measurements using the PM5-SA4 4-20mA plug-in module within your PoolManager controller, follow these steps: First, access the configuration menu by pressing the "Menu" hotkey on your PoolManager controller. Next, navigate to the "Communication & Interfaces" submenu, and then select the "Current outputs 4-20mA" submenu. Choose the specific current output associated with the measurement you want to configure; for example, select "Current output pH" if you're setting up the pH measurement. Within the submenu for your selected measurement, you'll be able to adjust the following parameters: The "Current output" setting will vary depending on the measurement type, such as pH, Cl, Br, mV, O2, or T1. You can also define the "Minimum value (at 4 mA)" which represents the beginning of your measurement range, and the "Maximum value (at 20 mA)," which defines the end of your measurement range. Note that each current output is identified by the plug-in connector number, typically connector 1, and the current output number on the PM5-SA4 module. The default allocation usually looks like this: Current output 1.1 corresponds to pH, 1.2 to Cl or Br, 1.3 to mV or O2, and 1.4 to temperature T1. By default, the minimum and maximum values are set as follows: pH: 0.00 to 10.00 pH, Cl or Br: 0.00 to 10.00 /l, mV: 0 to 1000 mV, O2: 0 to 10 l, and T1: 0°C to 50°C. Make sure to adjust these settings to align with your desired measuring range. Remember that the minimum value correlates with a 4 mA current signal, while the maximum value corresponds to a 20 mA current signal. For comprehensive details, please consult the BAYROL PM5-SA4 PoolManager PRO Analyt User Manual.