Priming your Hypro Self-Priming Centrifugal Pump correctly is essential for optimal performance. Here's how to do it effectively: First, fill the priming chamber. Unlike some pumps, only the priming chamber of a self-priming model needs to be filled with liquid. Avoid running the pump unless the priming chamber is completely full to prevent damage to the mechanical seal, which relies on the liquid for lubrication. To prime the pump, remove the filler cap, typically found on top where the discharge line connects, and fill the chamber with liquid until it reaches the level of the inlet port. After each use, flush and drain the priming chamber to prevent corrosion or freezing damage. Drain it by removing the lower drain plug located at the bottom of the casing. Before starting the engine, make sure the priming chamber is filled and the discharge hose is securely connected. Turn the engine switch to the ON position. Then, turn the fuel valve to ON. Slightly open the throttle lever. Adjust the choke lever based on the engine's temperature, using the choke when cold and not when warm. Start the engine by quickly and firmly pulling the recoil starter. Repeat until the engine starts. Following these steps will help you properly prime your Hypro Self-Priming Centrifugal Pump, ensuring it runs efficiently and reliably.