To effectively use your Cell2 Kuiper Lighthead Middle Linear 3LED lightbar, follow these steps. First, ensure you've properly completed the wiring following the manual's instructions: Connect the red power cable wire to a fused power source linked to the vehicle . Ground the black wire to the vehicle's chassis. Route the control wires to your switch panel, connecting the necessary wires. Important: Use only the function wires for activation, not the power wire(s). For Warning Mode, apply +VDC to the BROWN wire for warning mode 1 or the ORANGE wire for warning mode 2. Change flash patterns by briefly tapping +VDC to the YELLOW wire while in Warning Mode; a single tap advances to the next pattern, while three quick taps reset to the default pattern. Activate Dim Mode by applying the GREEN wire to +VDC when a warning mode is active. For Take-Down or Work Lights, apply +VDC to the BLUE wire for front side lights and the PURPLE wire for rear side lights. To use Alley Lights, apply +VDC to the GRAY wire for the right side and the WHITE wire for the left side. The lightbar offers several flash patterns, from Double to Ultra and Split. Remember to follow the wiring instructions closely. Avoid using a high-pressure washer to clean the lightbar to protect it and your warranty. If connections are faulty, the lightbar might malfunction or revert to default settings.