Installing your WATERMARK MPU6 Soft Touch Lavatory Drain is straightforward. Here's a step-by-step guide to ensure a proper installation: First, disassemble the drain by unscrewing the tail from the body. Then, unscrew the nut and remove the washer and bottom gasket from the drain body. Next, insert the remaining drain components into the sink from the top, ensuring the Watermark logo on the cap is oriented as desired. Now, reassemble the drain: place the bottom gasket on top of the nylon washer, then place the nylon washer on top of the nut. Screw the nut back onto the body, but avoid over-tightening. After this, secure the tail: apply Teflon tape to the threads on the tail and screw the tail back into the drain body. Finally, connect the drain to the trap and carefully check for any leaks. Important installation information: Always use Teflon tape or pipe sealant for threaded connections. Do not use plumber’s putty on brass components to prevent tarnishing; a non-corrosive Alkoxy Silicone is recommended. Note that the drain warranty covers mechanical failure only, not finish defects. For further assistance or technical support, contact Watermark Designs at 718-257-2800.