To install the Minden PFP2000 Pathfinder Single Tank Plumbing Kit on your tank, follow these steps. Begin by consulting the product usage instructions in the manual. First, install the 3" tank bung (TF300) and the 2" tank bung (TF200) into the tank, using appropriate tools. Next, attach the 3" valve (VSFMT300) to the 3" tank bung (TF300). Then, connect the 2" Kana flex Supply Hose (KF2390) to the 3" valve (VSFMT300). Following this, install the valve mount single tank (PF-CP-P132) on the tank. Attach the 2" HB x MPT x 90 (HB200-90) to the valve mount single tank (PF-CP-P132). Secure the 2" valve (VSF200CF) to the 2" HB x MPT x 90 (HB200-90) and connect the 2" Kana flex Supply Hose (KF2390) to the 2" valve (VSF200CF). Subsequently, attach the 2" HB X 2" MNFLD FLANGE (M200BRB) to the valve mount single tank (PF-CP-P132). Place the 2" MANIFOLD GASKET W/ SKIRT (M202G) between the valve mount single tank (PF-CP-P132) and the 2" HB X 2" MNFLD FLANGE (M200BRB). Attach the 2" HI TORQUE CLAMP (FC200) to the 2" HB X 2" MNFLD FLANGE (M200BRB). Finally, attach the 2" MOLDED CAP (200CAP) to the remaining tank bung (TF200) and valve mount single tank (PF-CP-P132). Using the appropriate tools, as outlined in the manual, is essential for a successful installation of your Minden PFP2000 Pathfinder Single Tank Plumbing Kit. For any difficulties or further assistance, contact Minden Machine Shop Inc..