Log in / Register

How do I install Armorlite JL 4-Door Rock Sliders on my Jeep?

1Answers
AliceAnn
12/17/2025, 11:35:08 AM

Installing Armorlite JL 4-Door Rock Sliders on your Jeep involves several key steps. Before you begin, put your vehicle in "Park" and engage the emergency brake. It is also recommended to wear gloves to protect your hands and have a second person to assist with the installation process.

Here are the tools you'll need:

  • 10 mm socket
  • Small standard screwdriver
  • T50 Torx head bit
  • 16 mm wrench
  • Trim stick

Follow these steps for the installation:

  1. Flooring Preparation: Protect seat side shields and remove both front and rear floor mats. Remove the front sill, electrical connector block, and door harness connector. Take out the front and rear seat bolts. Detach the B-pillar (both mid and lower sections). Remove the rear console bolt trim covers and bolts, followed by the front console bolt covers and bolts. If installing the rear flooring, remove the rear carpet. Then, take out the front factory carpets and unscrew the plastic floor mat posts. Finally, remove the factory plugs (2 front, 2 rear).
  2. Flooring Installation: Install the rear Armorlite flooring if applicable, followed by the front passenger side flooring and then the front driver side flooring.
  3. Reassembly: Reinstall the B-pillar, then the front sill. Secure the front and rear seat bolts to a torque specification of 48 newton meters. Reinstall the rear console bolts and trim covers, along with the front console bolts and trim covers.

Armorlite flooring products are covered by a limited lifetime warranty for materials and workmanship, valid for the original purchaser for as long as they own the vehicle. The warranty does not cover intentional damage, accidents, unreasonable use, neglect, improper installation, modifications, or damage prior to installation. To make a warranty claim, visit the support page on www.GoArmorlite.com and complete the form. You may need to provide images as proof of a manufacturing defect. Upon approval, Armorlite will provide a replacement product and cover shipping costs. For more detailed visual instructions, you can also view the installation video at www.GoArmorlite.com/installation.

Was this review help?
110
Share
More Q&A

How do I best care for my HMS SGZ 6 in 1 Weight Set's rubber cover to ensure it lasts?

To keep your HMS SGZ 6 in 1 Weight Set in top condition and ensure its longevity, follow these care and maintenance guidelines: Storage : Always store your weight set in a dry room when not in use. This helps prevent moisture damage, which can affect the rubber cover and the overall lifespan of the weights. Regular Inspections : Before each workout, thoroughly inspect the dumbbells. Check for any signs of wear and tear, such as cracks, tears, or loose parts. Do not use any dumbbells that appear damaged. Cleaning : Keep your HMS SGZ weight set clean. If the rubber cover gets dirty, simply wipe it down with paper towels. Avoid using harsh chemicals or abrasive cleaners, which could damage the rubber. Assembly and Disassembly : If your set requires assembly or disassembly, always use the spanners provided with the HMS SGZ set. Avoid disassembling the dumbbells unless absolutely necessary, as this could lead to damage or improper reassembly. Safe Storage : When your weight set isn't in use, store it in a safe and secure location. This will help prevent accidents and protect the weights from potential damage.
108
Share

How do I sync the remote with my Arte Confort Celia Ceiling Fan?

To sync your remote with your Arte Confort Celia Ceiling Fan, follow these steps: First, ensure the fan has no power. You can do this by turning off the wall switch that controls the fan or by disconnecting the quick connect cables from the fan if there is no switch. Next, resynchronize the remote control. Here's how, depending on your setup: Syncing One Remote to One Fan: Cut off the power to the fan and wait 30 seconds. Restore power to the fan. Within 10 seconds, press and hold the synchronization button on your remote control for 3 seconds until you hear a signal. The remote control should work within a range of 8-10 meters. Syncing One Remote to Multiple Fans: Cut off the power to all fans and wait 30 seconds. Restore power to all fans. Within 10 seconds, press and hold the "ON/OFF light" button on each remote control for 3 seconds until you hear a signal. If the fans are within 10 meters of each other, they should sync simultaneously. Syncing Remotes to Individual Fans (e.g., Two Fans): Cut off power to Fan A and wait 30 seconds. Cut off power to Fan B and wait 30 seconds. Restore power to Fan B. Within 10 seconds, press and hold the "ON/OFF light" button on Remote B for 3 seconds until you hear the signal to sync Remote B with Fan B. Cut off power to Fan B and wait 30 seconds. Restore power to Fan A. Within 10 seconds, press and hold the "ON/OFF light" button on Remote A for 3 seconds until you hear the signal to sync Remote A with Fan A. Repeat these steps for each fan and remote control combination. After following these instructions, your remote control should be successfully synchronized with your Arte Confort Celia Ceiling Fan. If you have any further questions or run into any problems, please consult your dealer or contact Arte Confort directly.
111
Share

How do I install the PHILIPS DDRC1220FR-GL Dynalite Relay Controller?

Installing the PHILIPS DDRC1220FR-GL Dynalite Relay Controller correctly is crucial for both safety and optimal performance. Here's a guide to help you through the process: Enclosure Installation: Always have a qualified electrician install the device inside an approved enclosure. This is vital to meet all local and national electrical codes and regulations. Voltage Verification: Confirm that the input voltage of the relay controller matches your building's electrical supply. Check the manual for the specific voltage ratings. FCC Compliance: The device complies with FCC regulations for Class B digital devices. If you experience interference, try adjusting the antenna, increasing the distance between the equipment and receiver, or consult a professional. Canadian ICES-003 Compliance: This device also adheres to Canadian ICES-003 standards. Ensure proper installation and usage to remain compliant with Canadian regulations. Temperature and Current Limits: When installing your home or building automation and control system, adhere to IEC 60364 standards. Specifically, make sure you do not exceed the temperature limits and current-carrying capacities for communication wires as outlined in IEC 60364-5-52. Manufacturer's Guidelines: Remember that any modifications not approved by the manufacturer could void your ability to operate the device. Always refer to the provided instructions and seek professional assistance when needed. By following these guidelines, you can ensure a safe and successful installation of your PHILIPS DDRC1220FR-GL Dynalite Relay Controller.
119
Share

How do I maintain my HMS SGZ 6 in 1 weight set rubber cover for optimal performance and safety?

To ensure the longevity and safe use of your HMS SGZ 6 in 1 weight set rubber cover, proper maintenance is key. Here are some essential care instructions: Storage: Always store your weight set in a dry room. This prevents moisture damage and corrosion. Inspection: Before each workout, thoroughly inspect the dumbbells for any signs of wear, tear, or damage. Discontinue use if any parts appear compromised. Cleaning: If your weight set gets dirty, simply wipe it down with paper towels to remove any dirt or grime. Assembly and Disassembly: Use only the provided spanners for any installation or removal procedures. Avoid attempting to disassemble the dumbbells, as this may lead to damage. Safe Storage: When not in use, store your HMS SGZ 6 in 1 weight set in a safe and secure location, away from potential hazards, to prevent accidents.
112
Share

How do I wire a NOTIFIER RA400Z RA400ZA Remote Annunciator to my fire alarm system

Wiring a NOTIFIER RA400Z RA400ZA Remote Annunciator involves several key steps. First, ensure proper mounting to a single-gang electrical outlet box, keeping in mind the device's voltage and temperature limitations; it's designed for indoor use. Pay close attention to polarity, connecting the incoming wires to the '+' and '-' terminals on the annunciator. If using with an intelligent system, you might need to break the tab on the device, as specified in the manual, which sets the minimum input voltage to 18 volts. Always verify compatibility with your existing fire alarm system by consulting the manufacturer, as the RA400Z RA400ZA is designed to work with certain NOTIFIER or System Sensor products. The annunciator draws power from the connected device, so ensure the primary system is continuously powered. Finally, install the RA400Z RA400ZA in a highly visible location, avoiding direct sunlight or intense lighting that could obscure the signals. Always consult the NOTIFIER RA400Z RA400ZA Remote Annunciators Instruction Manual for detailed guidance.
106
Share

How can I verify the voltage compatibility of my Accord Lighting 580 Clean Accord Wall Lamp with my power supply?

To ensure safe and proper operation, confirm that the Accord Lighting 580 Clean Accord Wall Lamp's voltage requirements match your home's mains supply before installation. You can usually find the required voltage printed on the lamp itself, its packaging, or in the product specifications. These specifications are provided by the manufacturer. If you're uncertain about compatibility, it's always best to consult with a qualified electrician. Matching the correct voltage is essential to prevent electrical problems and to protect your new wall lamp from damage.
101
Share
Cookie
Cookie Settings
© 2025 Servanan International Pte. Ltd.