Installing and leveling the EATON FAA L-862 High Intensity Runway Light Quartz (HRLQ) correctly is crucial for runway safety. Here's a step-by-step guide based on the instruction manual:
Installation of Light Fixtures:
- Slide the extension over the wire assembly and into the top of the base.
- Connect the wire assembly with the L-823 plug into the socket.
- Secure the frangible base to the base plate or stake mount and tighten it.
- Ensure the extension is fully seated in the frangible base and is vertical, then tighten the lower component.
- Rotate the optical sub-assembly until the arrow on the outer lens aligns with the runway centerline, and then tighten the upper component.
Leveling & Aligning Light Fixtures:
- Before leveling, remove the lock pin, clamp band, outer lens, and gasket.
- Use the adjustment screws to level the optical sub-assembly. For faster leveling and alignment, consider using the Crouse-Hinds P/N 40999 device.
Installing the Lamp:
- Insert the lamp into the lamp holder assembly.
- For DCR lamps, refer to specific installation instructions.
- Before operating, clean the lamp with alcohol and a soft cloth to avoid contamination.
Installing Inner Dome Assembly:
- When replacing the lamp, begin by removing the lock pin, clamp ring, and outer lens.
- Loosen the screws securing the lamp holder sub-assembly and remove it.
- Reassemble the components after replacing the lamp.
Re-Lamping (Bi-Pin and PK30d): Follow specific steps for lamp replacement, including removing the inner dome assembly and spring clips.
Re-Lamping (DCR): Follow specific instructions to remove the DCR lamp, including removing the inner dome and lamp holder sub-assembly.
By carefully following these steps from the EATON FAA L-862 (HRLQ) instruction manual, you can ensure your runway lights are installed and leveled properly for optimal performance and safety.