Setting up your Aube TH146-P-2H1C programmable thermostat involves a few key steps. First, ensure you have the control module (CT280-2H1C) and the user console (TH146-P). For installation, mount the control module near your HVAC system, away from heat sources. Place the user console in a central, indoor location, about 1.5 meters (5 feet) above the floor. Connect the console to the control module using any two wires previously connected to your old thermostat. Refer to the wiring table in the Aube TH146-P-2H1C installation guide that matches your system type (HVAC or Heat Pump) to connect essential devices such as the plenum sensor, outdoor sensor, and humidifier. For configuration, access the configuration switches on the back of the console. Set the Access Mode switch (SW1-1) to 'INST' for Installer mode or 'USER' for User mode. Use the Keypad Lock switch (SW1-2) to lock or unlock the keypad as needed. To configure thermostat settings, press the Mode button for three seconds to enter the configuration menu. Use the buttons to navigate and modify parameters. The thermostat offers Automatic, Manual, and Auto modes for heating/cooling changeover. You can set Balance Points to manage heat pump or auxiliary heating based on outdoor temperatures. Adjust Interstage Delay, Low/High-Temperature Limits, and Fan settings for optimal performance. You can program a pre-set schedule or manually adjust the temperature settings. Should you have any issues or questions during setup or operation, don't hesitate to contact Aube Technologies for support. The Aube TH146-P-2H1C comes with a three-year warranty, covering defects in workmanship and materials. Following the provided installation guide will ensure a successful setup of your Aube thermostat.