To properly wire your Echoflex ElahoAccess Interface, follow these steps for a successful installation: First, gather your wire termination kits and wire pigtails for 24 VDC auxiliary power and EchoConnect. You can install the station in a standard flush-mount or surface-mount back box. Next, bring all necessary wiring into the back box, including an ESD ground wire if needed. Terminate the ESD ground wire pigtail, connecting it to the Interface electronics. Use WAGO connectors to terminate the EchoConnect wires, ensuring correct pairing of the power pigtail and control wires. Then, connect the two-pin connector from the EchoConnect pigtail to its receptacle on the station electronics. For 24 VDC auxiliary power wiring, strip insulation from both the Auxiliary Power pigtail wires and the installed power wires. Connect these wires using WAGO connectors, making sure they are correctly paired. Finally, connect the two-pin connector from the Auxiliary Power pigtail to its corresponding receptacle on the station. Remember, all control wiring should be installed and terminated by a qualified installer following standard wiring practices. Always ensure proper grounding for ESD protection. Leave about 10 inches (25.4 cm) of extra wiring in the back box for future service. Adhering to these steps ensures your Echoflex ElahoAccess Interface is correctly wired for optimal performance.