Powering your Altronix NetWaySP2P Series switches correctly is crucial for optimal performance. Here's a breakdown for different models:
For NetWaySP2P and NetWaySP2PWPN: Connect a 48VDC to 56VDC power source to the terminals labeled [48-56VDC – Input +]. Be sure to match the positive and negative terminals. These terminals can handle up to 12 AWG wires.
For NetWaySP2PWP and NetWaySP2PWPX: Before connecting power, make sure the input voltage selection switch is set correctly. These units typically come pre-set for 115VAC. Connect AC power from a circuit breaker (20A @ 115VAC, 60Hz or 16A @ 230VAC, 50/60Hz) to the [L, N] terminals on the power supply board. Connect the ground lug to the earth or the green branch wire on the backplane (minimum 12AWG).
Backup (Optional): If you want battery backup, connect four 12VDC batteries in series to the terminals marked [– BAT +], paying close attention to polarity. Use lead-acid or gel-type batteries. Keep in mind, without batteries, a loss of AC power will result in loss of output voltage.
Important Safety Notes: Always be careful when working with electrical components. Make sure all power connections are secure to prevent any damage to your equipment. If you're unsure about any part of the installation, it's a good idea to get help from a trained professional to ensure everything is set up correctly.