To configure the Hot Start function on your GYS TIG 160 DC Lift Single Phase Welder, follow these steps: First, briefly press the selector button (5). The "MMA" will begin to flash, and the display (1) will show the current Hot Start value. Next, use the keys (4) to set your desired Hot Start percentage, within a range of 0% to 60%. Once you've chosen your setting, press the selector button (5) again to validate it. The "MMA" LED will stay lit, confirming that the Hot Start function is active. Remember to use a lower Hot Start setting when welding thin metal sheets and a higher setting for metals that are challenging to weld, such as those with dirt or oxidation. Adjusting the Hot Start feature can greatly enhance electrode starting performance and help avoid sticking issues. Always consult the GYS TIG 160 DC Lift Single Phase Welder Instruction Manual for the most accurate instructions and crucial safety guidance.