To configure your FHCRX-1V2 and FHCRX-2V2 Multi-Frequency Receivers for various modes, follow these instructions: Pulse Mode allows the relay to activate while the transmitter button is held. For Relay-1 Pulse Mode, ensure the JP1 jumper is removed, meaning the two pins are not connected. For Relay-2 Pulse Mode, remove the JP2 jumper. Hold Mode toggles the relay state with each press of the transmitter button. To enable Hold Mode for Relay-1, bridge the two pins on the JP1 jumper. For Relay-2 Hold Mode, bridge the two pins on the JP2 jumper. Timer Mode keeps the relay active for a preset duration, adjustable from 0 to 655.34 seconds in 0.01-second increments. Note that Timer Mode configuration requires the ATA Programmer. Properly setting these modes allows you to tailor the receiver's behavior for controlling devices such as garage doors or gate openers.