To confirm that your ILBLP CP HE SD Emergency LED Driver is operating correctly, follow these steps:
-
Normal Operation:
- When AC power is available, the TBTS light should be illuminated, indicating that the battery is charging.
- The AC Driver will power the LED Module as expected.
-
Emergency Operation:
- In the event of a power outage, the ILBLP CP HE SD automatically switches to emergency mode.
- The LED Module will activate at a reduced brightness, providing light for at least 90 minutes.
- Once AC power is restored, the system returns to normal operation and resumes charging the battery.
-
Testing Procedures:
- The system performs automatic tests monthly for 60 seconds and annually for 90 minutes.
- The TBTS assembly conducts self-tests; any failures are indicated by the flashing of its bi-color LED. Consult Table A in the manual for specific diagnostic codes.
-
Manual Testing:
- Initiate manual testing by pressing and holding the TBTS test button for two seconds when the TBTS status indicator light is green.
- Manual tests run for 60 seconds and can be stopped by holding the TBTS button for at least two seconds.
By monitoring these indicators and following these testing steps, you can confidently ensure your ILBLP CP HE SD Emergency LED Driver functions correctly in both normal and emergency situations, as per the manufacturer's specifications.