What are the causes of compressor burnout?
1 Answers
Compressor burnout is caused by: 1. Frequent starting of the air conditioning compressor; 2. Unstable power supply voltage of the air conditioning system; 3. Insufficient cleanliness of the air conditioning copper pipe system; 4. Jamming of the rotating parts of the air conditioning compressor; 5. Incomplete cleaning of the refrigeration system after the air conditioning compressor burns out; 6. Poor cooling of the air conditioning compressor; 7. Manufacturing defects in the air conditioning compressor itself; 8. Faulty starting contactor of the air conditioning compressor. A compressor is a type of driven fluid machinery that converts low-pressure gas into high-pressure gas, serving as the heart of the refrigeration system. It draws in low-temperature, low-pressure refrigerant gas through the suction pipe, compresses it via the operation of the motor-driven piston, and then discharges high-temperature, high-pressure refrigerant gas through the discharge pipe, providing power for the refrigeration cycle.